Počet záznamů: 1  

Diamond detectors for time-of-flight measurements in laser-generated plasmas

  1. 1.
    SYSNO ASEP0331187
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevDiamond detectors for time-of-flight measurements in laser-generated plasmas
    Překlad názvuDiamantové detektory pro měření doby průletu v laserem generovaném plazmatu
    Tvůrce(i) Torrisi, L. (IT)
    Margarone, D. (IT)
    Milani, E. (IT)
    Verona-Rinati, G. (IT)
    Prestopino, G. (IT)
    Tuvè, C. (IT)
    Potenza, R. (IT)
    Láska, Leoš (FZU-D)
    Krása, Josef (FZU-D) RID, ORCID
    Ullschmied, Jiří (UFP-V) RID
    Zdroj.dok.Radiation Effects and Defects in Solids. - : Taylor & Francis - ISSN 1042-0150
    Roč. 164, 5-6 (2009), s. 369-375
    Poč.str.7 s.
    AkceWorkshop on European Collaboration for Higher Education and Research in Nuclear Engineering and Radiological Protection /4./
    Datum konání26.05.2008-28.05.2008
    Místo konáníFavignana
    ZeměIT - Itálie
    Typ akceEUR
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovadiamond detector ; laser-generated plasma ; x-ray detection
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    CEPLC528 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    CEZAV0Z10100523 - FZU-D (2005-2011)
    AV0Z20430508 - UFP-V (2005-2011)
    UT WOS000266032900018
    DOI10.1080/10420150902811763
    AnotaceCVD mono-crystalline diamond thin films deposited on a doped diamond were employed as detectors of the radiation emitted from the laser-generated plasma. Plasmas were obtained by ablating Al, Ta, Au, and CF2 bulk targets by the use of an Nd:Yag repetitive laser at INFN-LNS in Catania operating at 10e10W/cm2 pulse intensity, and by a high-power iodine PALS laser in Prague operating at 10e15W/cm2 pulse intensity. Diamond detectors can measure UV, X-rays, electrons, and ions. The time-of-flight (TOF) technique was exploited to separate photon, electron, and particle contributions. The TOF diamond spectra were compared with traditional ion collector spectra. The results indicate that the ion energy resolution of the employed diamond detectors is high and that the fast electrons can be detected from a deconvolution procedure applied to the fast photo-peak.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2010
Počet záznamů: 1  