Počet záznamů: 1  

Volume reconstruction of large tissue specimens from serial physical sections using confocal microscopy and correction of cutting deformations by elastic registration

  1. 1.
    SYSNO ASEP0323668
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevVolume reconstruction of large tissue specimens from serial physical sections using confocal microscopy and correction of cutting deformations by elastic registration
    Překlad názvuObjemová rekonstrukce velkých biologických tkáňových vzorků ze sériových fyzických řezů s použitím konfokální mikroskopie a korekce deformací elastickou deformací
    Tvůrce(i) Čapek, Martin (FGU-C) RID, ORCID
    Brůža, Petr (FGU-C)
    Janáček, Jiří (FGU-C) RID, ORCID
    Karen, Petr (FGU-C)
    Kubínová, Lucie (FGU-C) RID, ORCID
    Vagnerová, R. (CZ)
    Zdroj.dok.Microscopy Research and Technique - ISSN 1059-910X
    Roč. 72, č. 2 (2009), s. 110-119
    Poč.str.10 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slova3D reconstruction ; elastic registration ; confocal microscopy
    Vědní obor RIVJD - Využití počítačů, robotika a její aplikace
    CEPIAA100110502 GA AV ČR - Akademie věd
    IAA500200510 GA AV ČR - Akademie věd
    GA102/08/0691 GA ČR - Grantová agentura ČR
    LC06063 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    CEZAV0Z50110509 - FGU-C (2005-2011)
    UT WOS000263511100008
    DOI10.1002/jemt.20652
    AnotaceA set of methods leading to volume reconstruction of biological specimens larger than the field of view of a confocal laser scanning microscope (CLSM) is presented. Large tissue specimens are cut into thin physical slices and volume data sets are captured from all studied physical slices by CLSM. Overlapping spatial tiles of the same physical slice are stitched in horizontal direction. Image volumes of successive physical slices are linked in axial direction by applying an elastic registration algorithm to compensate for deformations due to cutting the specimen. We present a method enabling us to keep true object morphology using a-priori information about the shape and size of the specimen, available from images of the cutting planes captured by a USB light microscope immediately before cutting the specimen by a microtome. The errors introduced by elastic registration are evaluated using a stereological point counting method and the Procrustes distance