Počet záznamů: 1  

Surface plasmon resonance sensor for detection of bisphenol A in drinking water

  1. 1.
    0350306 - ÚFE 2011 RIV CH eng J - Článek v odborném periodiku
    Hegnerová, Kateřina - Homola, Jiří
    Surface plasmon resonance sensor for detection of bisphenol A in drinking water.
    Sensors and Actuators B - Chemical. Roč. 151, č. 1 (2010), s. 177-179. E-ISSN 0925-4005
    Grant CEP: GA AV ČR KAN200670701
    Výzkumný záměr: CEZ:AV0Z20670512
    Klíčová slova: surface plasmon resonance biosensor * bisphenol A * drinking water
    Kód oboru RIV: JB - Senzory, čidla, měření a regulace
    Impakt faktor: 3.368, rok: 2010

    We reported detection of bisphenol A (BpA) in drinking water using a compact surface plasmon resonance (SPR) sensor and binding inhibition detection format. This method does not require any special treatment of water samples – after filtration, the pH and salt content of analyzed water are adjusted to those of the phosphate buffered saline (PBS). We demonstrate that this approach allows detection of BpA in drinking water down to 40 pg/ml in less than 35 min.