Počet záznamů: 1  

Active Front-End of Electric Drive under Unbalanced Voltage Supply

  1. 1.
    0352568 - ÚT 2011 RIV IT eng C - Konferenční příspěvek (zahraniční konf.)
    Chomát, Miroslav - Schreier, Luděk - Bendl, Jiří
    Active Front-End of Electric Drive under Unbalanced Voltage Supply.
    SPEEDAM 2010 - International Symposium on Power Electronics,Electrical Drives, Automation and Motion. Pisa: IEEE, 2010, s. 227-232. ISBN 978-1-4244-7919-1.
    [SPEEDAM 2010 - International Symposium on Power Electronics,Electrical Drives, Automation and Motion. Pisa (IT), 14.06.2010-16.06.2010]
    Grant CEP: GA ČR GA102/09/1273
    Výzkumný záměr: CEZ:AV0Z20570509
    Klíčová slova: DC-link voltage pulsations * pulse-width modulation * unbalanced voltage supply
    Kód oboru RIV: JA - Elektronika a optoelektronika, elektrotechnika

    Voltage-unbalance conditions that can arise in the power network may affect operation of electric drives in a negative way. The cause of the unbalance may be a failure in the network or presence of an unbalanced load in the vicinity of the affected drive. Unsymmetrical system of voltages at the input of a voltage source inverter gives rise to the pulsations in the DC link voltage when no suitable countermeasures are taken. The effect of the unbalanced voltage supply on the system has been investigated. The influence of some circuit parameters on operation of the system was also dealt with.
    Trvalý link: http://hdl.handle.net/11104/0192050

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.