Voltammetric Determination of Genotoxic Nitro Derivatives of Fluorene and 9-Fluorenone Using a Mercury Meniscus Modified Silver Solid Amalgam Electrode

  1. 1.
    0346605 - ÚFCH JH 2011 RIV DE eng J - Článek v odborném periodiku
    Vyskočil, V. - Navrátil, Tomáš - Polášková, P. - Barek, J.
    Voltammetric Determination of Genotoxic Nitro Derivatives of Fluorene and 9-Fluorenone Using a Mercury Meniscus Modified Silver Solid Amalgam Electrode.
    Electroanalysis. Roč. 22, 17-18 (2010), s. 2034-2042. ISSN 1040-0397. E-ISSN 1521-4109.
    [International Conference on Modern Electroanalytical Methods. Prague, 09.12.2009-14.12.2009]
    Grant CEP: GA AV ČR IAA400400806
    Výzkumný záměr: CEZ:AV0Z40400503
    Klíčová slova: voltammetry * Silver solid amalgam electrode * drinking water
    Kód oboru RIV: CG - Elektrochemie
    Impakt faktor: 2.721, rok: 2010

    Voltammetric behavior of selected genotoxic nitro compounds (2-nitrofluorene, 2,7-dinitrofluorene, 2-nitro-9-fluorenone and 2,7-dinitro-9-fluorenone) has been investigated using direct current voltammetry (DCV), differential pulse voltammetry (DPV) and adsorptive stripping differential pulse voltammetry (AdSDPV) at a mercury meniscus modified silver solid amalgam electrode (m-AgSAE). The optimum conditions have been found for their determination in a 1 : 1 mixture of methanol and aqueous Britton–Robinson buffer solution, with the limits of quantification, (LOQ), 2, 0.3, 0.5, and 0.5 μmol L−1 (DCV at m-AgSAE) and 0.2, 0.2, 0.4, and 0.2 μmol L−1 (DPV at m-AgSAE) for 2-nitrofluorene, 2,7-dinitrofluorene, 2-nitro-9-fluorenone, and 2,7-dinitro-9-fluorenone, respectively. An attempt at increasing the sensitivity using AdSDPV at m-AgSAE was successful only for 2-nitrofluorene (LOQ=2 nmol L−1).
    Trvalý link: http://hdl.handle.net/11104/0187589

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.