Počet záznamů: 1  

In Vivo Contrast Imaging of Rat Heart with Carbon Dioxide Foam

  1. 1.
    SYSNO ASEP0559871
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevIn Vivo Contrast Imaging of Rat Heart with Carbon Dioxide Foam
    Tvůrce(i) Karalko, A. (CZ)
    Keša, P. (CZ)
    Jelínek, F. (CZ)
    Šefc, L. (CZ)
    Ježek, Jan (UPT-D) RID, ORCID, SAI
    Zemánek, Pavel (UPT-D) RID, SAI, ORCID
    Grus, T. (CZ)
    Celkový počet autorů7
    Číslo článku5124
    Zdroj.dok.Sensors. - : MDPI - ISSN 1424-8220
    Roč. 22, č. 14 (2022)
    Poč.str.11 s.
    Forma vydáníOnline - E
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovacarbon dioxide foam ; angiography ; contrast-enhanced ultrasound imaging ; preclinical imaging
    Vědní obor RIVBO - Biofyzika
    Obor OECDBiophysics
    CEPEF16_013/0001775 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Výzkumná infrastrukturaCzech-BioImaging - 90062 - Ústav molekulární genetiky AV ČR, v. v. i.
    Způsob publikováníOpen access
    Institucionální podporaUPT-D - RVO:68081731
    UT WOS000832426000001
    EID SCOPUS85133518791
    DOI https://doi.org/10.3390/s22145124
    AnotaceWidely used classical angiography with the use of iodine contrast agents is highly problematic, particularly in patients with diabetes mellitus, cardiac and pulmonary diseases, or degree III or IV renal insufficiency. Some patients may be susceptible to allergic reaction to the iodine contrast substance. The intravenous injection of a bolus of CO2 (negative contrast) is an alternative method, which is, however, currently only used for imaging blood vessels of the lower limbs. The aim of our project was to design and test on an animal model a methodology for injecting the CO2 foam which would minimize the possibility of embolization of the brain tissue and heart infarction, leading to their damage. This is important research for the further promotion of the use of CO2, which is increasingly important for endovascular diagnosis and treatment, because carbon-dioxide-related complications are extremely rare. CO2 foam was prepared by the rapid mixing in a 2:1 ratio of CO2 and fetal bovine serum (FBS)-enriched Dulbecco's Modified Eagle Medium (DMEM). Freshly prepared CO2 foam was administered into the catheterized rat tail vein or cannulated rat abdominal aorta and inferior vena cava (IVC). CO2 foam was compared with commercially available microbubbles (lipid shell/gas core). The rat heart in its parasternal long axis was imaged in B-Mode and Non-linear Contrast Mode before/during and after the contrast administration. Samples of the brain, heart and lungs were collected and subjected to histological examination. The non-linear contrast imaging method enables the imaging of micron-sized gas microbubbles inside a rat heart. The significantly shorter lifetime of the prepared CO2 foam is a benefit for avoiding the local ischemia of tissues.
    PracovištěÚstav přístrojové techniky
    KontaktMartina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178
    Rok sběru2023
    Elektronická adresahttps://www.mdpi.com/1424-8220/22/14/5124