- EXILL - a high-efficiency, high-resolution setup for gamma-spectrosco…
Počet záznamů: 1  

EXILL - a high-efficiency, high-resolution setup for gamma-spectroscopy at an intense cold neutron beam facility

  1. 1.
    SYSNO ASEP0482518
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevEXILL - a high-efficiency, high-resolution setup for gamma-spectroscopy at an intense cold neutron beam facility
    Tvůrce(i) Jentschel, M. (FR)
    Blanc, A. (FR)
    de France, G. (FR)
    Koster, U. (FR)
    Leoni, S. (IT)
    Mutti, P. (FR)
    Simpson, G. S. (FR)
    Krtička, M. (CZ)
    Tomandl, Ivo (UJF-V) RID, ORCID, SAI
    Valenta, S. (CZ)
    Celkový počet autorů133
    Číslo článkuP11003
    Zdroj.dok.Journal of Instrumentation. - : Institute of Physics Publishing - ISSN 1748-0221
    Roč. 12, č. 11 (2017)
    Poč.str.33 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovainstrumentation for neutron sources ; gamma detectors ; spectrometers
    Vědní obor RIVBM - Fyzika pevných látek a magnetismus
    Obor OECDNuclear physics
    Institucionální podporaUJF-V - RVO:61389005
    UT WOS000414625700003
    DOI https://doi.org/10.1088/1748-0221/12/11/P11003
    AnotaceIn the EXILL campaign a highly efficient array of high purity germanium (HPGe) detectors was operated at the cold neutron beam facility PF1B of the Institut Laue-Langevin (ILL) to carry out nuclear structure studies, via measurements of gamma-rays following neutron-induced capture and fission reactions. The setup consisted of a collimation system producing a pencil beam with a thermal capture equivalent flux of about 10(8) ns(-1)cm(2) at the target position and negligible neutron halo. The targetwas surrounded by an array of eight to ten anti-Compton shielded EXOGAMClover detectors, four to six anti-Compton shielded large coaxial GASP detectors and two standard Clover detectors. For a part of the campaign the array was combined with 16 LaBr3:(Ce) detectors from the FATIMA collaboration. The detectorswere arranged in an array of rhombicuboctahedron geometry, providing the possibility to carry out very precise angular correlation and directional-polarization correlation measurements. The triggerless acquisition system allowed a signal collection rate of up to 6 x 10(5) Hz. The data allowed to set multi-fold coincidences to obtain decay schemes and in combination with the FATIMA array of LaBr3:(Ce) detectors to analyze half-lives of excited levels in the pico-to microsecond range. Precise energy and efficiency calibrations of EXILL were performed using standard calibration sources of Ba-133, Co-60 and Eu-152 as well as data from the reactions Al-27(n, gamma)Al-28 and Cl-35(n,gamma)Cl-36 in the energy range from 30 keV up to 10MeV.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2018
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.