Počet záznamů: 1  

Positioning system and lattice design for subaperture stitching interferometry

  1. 1.
    SYSNO ASEP0469292
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevPositioning system and lattice design for subaperture stitching interferometry
    Tvůrce(i) Kredba, Jan (UFP-V) ORCID
    Psota, Pavel (UFP-V) RID, ORCID
    Číslo článku101510G
    Zdroj.dok.Proceedings of SPIE 10151, Optics and Measurement International Conference 2016, OAM 2016 Proceedings, 10151. - Bellingham : SPIE, Society of Photo-Optical Instrumentation Engineers, 2016 / Kovačičinová J. - ISSN 0277-786X - ISBN 978-1-5106-0753-8
    Poč.str.12 s.
    Forma vydáníTištěná - P
    AkceOAM 2016, Optics and Measurement International Conference 2016
    Datum konání11.10.2016 - 14.10.2016
    Místo konáníLiberec
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovainterferometry ; lattice design ; positioning system ; metrology
    Vědní obor RIVJA - Elektronika a optoelektronika, elektrotechnika
    CEPLO1206 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    TA03010893 GA TA ČR - Technologická agentura ČR
    Institucionální podporaUFP-V - RVO:61389021
    UT WOS000393154700016
    EID SCOPUS85012907539
    DOI https://doi.org/10.1117/12.2257310
    AnotaceThe demands on the quality of large aperture spherical and mild aspheric optical surfaces continue to rise in modern optical systems. Due to the aperture size of these surfaces measuring of their shape is quite problematic. One of the ways to measure these surfaces is the subaperture stitching interferometry. Its accuracy is highly depended on lattice design and accuracy of the positioning system. Optimal lattice design in relation to transmission element applied in interferometer together with coordinates calculation for the positioning system for measuring individual subapertures is the subject of this paper. To set the required orientation and position of the optical surface relative to the interferometer positioning system with six degrees of freedom was used. Three of them were realized as prismatic kinematic pairs and remaining three as revolution joints. In this paper the choice of coordinate systems for individual axes of the positioning system together with inverse kinematics used for setting the correct position and orientation of the optical surface are described.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975