- The instrumental resolution of a moire extensometer in light of its r…
Počet záznamů: 1  

The instrumental resolution of a moire extensometer in light of its recent automatisation

  1. 1.
    SYSNO ASEP0466655
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevThe instrumental resolution of a moire extensometer in light of its recent automatisation
    Tvůrce(i) Rowberry, Matthew David (USMH-B) RID, ORCID, SAI
    Kriegner, D. (CZ)
    Holý, V. (CZ)
    Frontera, C. (ES)
    Llull, M. (ES)
    Olejník, Kamil (FZU-D) RID, ORCID
    Martí, Xavier (FZU-D) RID, ORCID
    Zdroj.dok.Measurement. - : Elsevier - ISSN 0263-2241
    Roč. 91, SEP (2016), s. 258-265
    Poč.str.8 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovageological discontinuity monitoring ; mechanical extensometer ; moire patterns ; instrumental resolution
    Vědní obor RIVJB - Senzory, čidla, měření a regulace
    Vědní obor RIV – spolupráceFyzikální ústav - Fyzika pevných látek a magnetismus
    CEPLM2010008 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUSMH-B - RVO:67985891 ; FZU-D - RVO:68378271
    UT WOS000379507400031
    EID SCOPUS84970024659
    DOI https://doi.org/10.1016/j.measurement.2016.05.048
    AnotaceThis paper assesses the instrumental resolution of a mechanical extensometer in light of its recent automatisation. The instrument takes advantage of the moire phenomenon of optical interference to measure angular rotation in two perpendicular planes and displacement in three dimensions. Our assessment systematically defines an analytical solution for the complete interpretation of a generic moire pattern and a set of mathematical approximations for the moire patterns used to measure rotation and displacement. The ultimate sensitivity of the automated instrument is determined on the basis of a generic least square differences fitting procedure while the instrumental resolution is defined on the basis of realistic, rather than optimal, scenarios: the resolution of the rotation measurements are in the order of 8.7 * 10(-5) rad while the resolution of the displacement measurements are better than 5 mu m. This assessment represents the first step towards a global numerical repository for processed data recorded by the automated extensometers.
    PracovištěÚstav struktury a mechaniky hornin
    KontaktIva Švihálková, svihalkova@irsm.cas.cz, Tel.: 266 009 216
    Rok sběru2017
Počet záznamů: 1  

Metadata v repozitáři ASEP jsou licencována pod licencí CC0.

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.