Quality assessment of scintillation detector in SEM using MFT

  1. 1.
    SYSNO ASEP0386386
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevQuality assessment of scintillation detector in SEM using MFT
    Tvůrce(i) Bok, Jan (UPT-D) RID
    Schauer, Petr (UPT-D) RID, SAI, ORCID
    Celkový počet autorů2
    Zdroj.dok.Proceedings of the 13th International Seminar on Recent Trends in Charged Particle Optics and Surface Physics Instrumentation. - Brno : Institute of Scientific Instruments AS CR, v.v.i, 2012 / Mika F. - ISBN 978-80-87441-07-7
    Rozsah strans. 9-10
    Poč.str.2 s.
    Forma vydáníTištěná - P
    AkceInternational Seminar on Recent Trends in Charged Particle Optics and Surface Physics Instrumentation /13./
    Datum konání25.06.2012-29.06.2012
    Místo konáníSkalský dvůr
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovascintillation detector in SEM ; modulation transfer function ; e-beam scanning speed
    Vědní obor RIVJA - Elektronika a optoelektronika, elektrotechnika
    CEPGAP102/10/1410 GA ČR - Grantová agentura ČR
    EE.2.3.20.0103 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUPT-D - RVO:68081731
    AnotaceOne of the recent trends in S(T)EM is increasing of the e-beam scanning speed. In general, higher speeds decrease object degradation and prevent image artifacts caused by slow electrical discharging. However, the increase of the scanning speed is limited by the time response of the segnal-electron detector. When the detector response is slower than the scanning speed, it can have negative influence to the quality of the scanned image, such as contrast reduction and image blurring. Usually, the rise and fall edges of the time response curve to a square electron pulse have more complex form, such as a multi-exponential function of time. Evaluate and compare the time-dependent edges in contex of their influence on the image quality is rather complicated. Therefore, we propose to express the detector time response by the modulation transfer function (MTF), which contains all relevant information. It can give the answer to the important question, what maximum scanning speed can be used not to significantly decrease the image quality.