Measurement Accuracy of a Mono-fiber Optical Probe in a Bubbly Flow
- 1.0343074 - ÚCHP 2011 RIV GB eng J - Článek v odborném periodiku
Vejražka, Jiří - Večeř, M. - Orvalho, Sandra - Sechet, Ph. - Růžička, Marek - Cartellier, A.
Measurement Accuracy of a Mono-fiber Optical Probe in a Bubbly Flow.
International Journal of Multiphase Flow. Roč. 36, č. 7 (2010), s. 533-548. ISSN 0301-9322. E-ISSN 1879-3533
Grant CEP: GA ČR GA104/07/1110; GA ČR GP104/06/P287; GA AV ČR(CZ) IAA200720801
Výzkumný záměr: CEZ:AV0Z40720504
Klíčová slova: optical probe * bubble-fiber interaction * void fraction
Kód oboru RIV: CI - Průmyslová chemie a chemické inženýrství
Impakt faktor: 1.772, rok: 2010
The measurement accuracy of a mono-fiber optical probe is studied experimentally using isolated bubbles rising freely in a still liquid. The dwell time of the probe tip within the gas phase, which is obtained from both the optical probe signal and high-speed visualization, is compared with the dwell time expected for a non-perturbed bubble. The measurement error results mainly from the intrusive nature of the optical probe, which modifies the behavior of the bubble when it comes into contact with the probe tip. The measured dwell time therefore differs from its ideal value that would be found with an unperturbed bubble. For a wetting liquid, the interaction increases the dwell time if the bubble is pierced near its pole, and shortens it for piercing near the equator. It is shown that the error can be correlated with a modified Weber number, and this correlation is helpful for sensor selection and for uncertainty estimate.