- Electrochemical microbead-based immunoassay using an (.eta..sup.5./su…
Počet záznamů: 1  

Electrochemical microbead-based immunoassay using an (.eta..sup.5./sup.-cyclopentadienyl)tricarbonylmanganese redox marker bound to bovine serum albumin

  1. 1.
    SYSNO ASEP0026099
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JOstatní články
    NázevElectrochemical microbead-based immunoassay using an (.eta.5-cyclopentadienyl)tricarbonylmanganese redox marker bound to bovine serum albumin
    Překlad názvuPoužití .eta.5-cyklopentadienyl trikarbonyl manganu jako redox značky bovin sérum albuminu při elektrochemické imunoanalýze s užitím mikronosičů
    Tvůrce(i) Hromadová, Magdaléna (UFCH-W) RID, ORCID, SAI
    Salmain, M. (FR)
    Fischer-Durand, N. (FR)
    Pospíšil, Lubomír (UFCH-W) RID, ORCID
    Jaouen, G. (FR)
    Zdroj.dok.Langmuir - ISSN 0743-7463
    Roč. 22, - (2005), s. 506-511
    Poč.str.6 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaelectrochemistry ; bovine serum albumin ; antigen-antibody complex
    Vědní obor RIVCG - Elektrochemie
    CEPGA203/03/0821 GA ČR - Grantová agentura ČR
    IAA400400505 GA AV ČR - Akademie věd
    LC510 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    CEZAV0Z40400503 - UFCH-W (2005-2011)
    AnotaceA first example of the solid-phase immunoassay of a high-wight antigen bovine serum albumin (BSA) using an (.eta.5-cyclopentadienyl)tricarbonylmanganese (cymantrene) redox probe is presented. The electrochemical detection is based on the impedance measurements of a one-electron reversible reduction of the organometallic probe. The microbeadbased immunoassay is discussed for two types of microbeads with different diameters (2.5 and 90 .mu.m) and capabilities to bind the immunoglobulins (2.4 and 10 .mu.g/mg of beads). The use of larger agarose microbeads allows the formation of an antigen-antibody complex at the surface of microbeads directly dispersed in the analyzed solution. No additional separation step is necessary for the electrochemical competitive immunoassay analysis of BSA. The presence of agarose beads in the analyzed solution has no effect on the electrochemical signal from labeled BSA released from the antigen-antibody complex.
    PracovištěÚstav fyzikální chemie J.Heyrovského
    KontaktMichaela Knapová, michaela.knapova@jh-inst.cas.cz, Tel.: 266 053 196
    Rok sběru2006
Počet záznamů: 1  

Metadata v repozitáři ASEP jsou licencována pod licencí CC0.

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.