Počet záznamů: 1  

Six MeV proton acceleration from plasma generated by high-intensity laser using advanced thin polyethylene targets

  1. 1.
    SYSNO ASEP0543958
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevSix MeV proton acceleration from plasma generated by high-intensity laser using advanced thin polyethylene targets
    Tvůrce(i) Torrisi, L. (IT)
    Cutroneo, Mariapompea (UJF-V) ORCID, RID, SAI
    Torrisi, A. (IT)
    Celkový počet autorů3
    Číslo článku202100024
    Zdroj.dok.Contributions to Plasma Physics. - : Wiley - ISSN 0863-1042
    Roč. 61, č. 8 (2021)
    Poč.str.14 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.DE - Německo
    Klíč. slovaion acceleration ; laser-plasma ; polyethylene ; SiC detector TNSA
    Vědní obor RIVBG - Jaderná, atomová a mol. fyzika, urychlovače
    Obor OECDAtomic, molecular and chemical physics (physics of atoms and molecules including collision, interaction with radiation, magnetic resonances, Mössbauer effect)
    Způsob publikováníOmezený přístup
    Institucionální podporaUJF-V - RVO:61389005
    UT WOS000670173500001
    EID SCOPUS85109172121
    DOI10.1002/ctpp.202100024
    AnotaceProton acceleration can be induced by non-equilibrium plasma developed by high-intensity laser pulses, at 10(16) W/cm(2), irradiating different types of thin polyethylene targets. The process of proton acceleration and directive yield emission was investigated, optimizing the laser parameters, the irradiation conditions, and the target properties. The use of 600 J pulse energy, a laser focalization inducing self-focusing effects and advanced targets with embedded nanoparticles and optimal thicknesses, has permitted to accelerate forward protons up to the energies of about 6 MeV and amount of the order of 10(15) H+/pulse. High proton energy is obtained using thin foils enriched with gold nanoparticles, whereas high proton yield is obtained using targets with a thickness of about 10 mu m. The plasma diagnostics using SiC semiconductor detectors in time-of-flight configuration was fundamental to monitor the optimal conditions to improve the plasma processes concerning the ion acceleration and the X-ray and relativistic electron emission.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2022
    Elektronická adresahttps://doi.org/10.1002/ctpp.202100024
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.