- Suspended nanophotonic waveguide for isotope-specific CO2 detection
Počet záznamů: 1  

Suspended nanophotonic waveguide for isotope-specific CO2 detection

  1. 1.
    SYSNO ASEP0605169
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevSuspended nanophotonic waveguide for isotope-specific CO2 detection
    Tvůrce(i) Salaj, J. (SK)
    Vlk, M. (CZ)
    Zakoldaev, R. (RU)
    Seton, R. (SE)
    Čtyroký, Jiří (URE-Y) RID
    Alberti, S. (AR)
    Aksnes, A. (NO)
    Jágerská, J. (CZ)
    Celkový počet autorů8
    Zdroj.dok.Optica. - : Optical Society of America - ISSN 2334-2536
    Roč. 11, č. 12 (2024), s. 1654-1662
    Poč.str.9 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaOptical waveguides ; laser spectrometer ; Nanophotonic waveguides
    Obor OECDOptics (including laser optics and quantum optics)
    CEPEH22_008/0004573 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOmezený přístup
    Institucionální podporaURE-Y - RVO:67985882
    UT WOS001398034200008
    EID SCOPUS85213240573
    DOI https://doi.org/10.1364/OPTICA.533710
    AnotaceThe spectroscopic detection of gases and their stable isotopes holds significant value in bio-sciences and climate studies. However, achieving high precision has long been confined to bulky and costly equipment. In this work, we introduce a nanophotonic waveguide that is capable of detecting CO2 gas down to 20 parts per billion, and for the first time perform accurate stable isotope ratio measurements. The waveguide leverages a suspended membrane design with microstructured cladding, providing a high evanescent field confinement factor of 102%, moderate loss of 3.4 dB/cm, and effective suppression of etalons. The delta 13C isotope ratio precision of 0.2 parts per thousand was achieved, replicating the performance of high-end laser absorption spectrometers. This marks the inaugural instance of on-chip, isotope-specific gas detection with a compact and cost-efficient system scalable to sensor