Počet záznamů: 1
Nonrigid Registration of CLSM Images of Physical Sections with Discontinuous Deformations
- 1.0369509 - FGÚ 2012 RIV US eng J - Článek v odborném periodiku
Michálek, Jan - Čapek, Martin - Kubínová, Lucie
Nonrigid Registration of CLSM Images of Physical Sections with Discontinuous Deformations.
Microscopy and Microanalysis. Roč. 17, č. 6 (2011), s. 923-936. ISSN 1431-9276. E-ISSN 1435-8115
Grant CEP: GA ČR(CZ) GA102/08/0691; GA ČR(CZ) GA304/09/0733; GA MŠMT(CZ) LC06063; GA MŠMT(CZ) ME09010; GA MŠMT(CZ) MEB0810092
Výzkumný záměr: CEZ:AV0Z50110509
Klíčová slova: confocal microscopy * image registration * target image * reference image * total variation * data term * smoothness term * L1-TV function * E-L1-TV function * graph cuts * multilabel optimization * local entropy
Kód oboru RIV: JC - Počítačový hardware a software
Impakt faktor: 3.007, rok: 2011
When biological specimens are cut into physical sections for three-dimensional (3D) imaging by confocal laser scanning microscopy, the slices may get distorted or ruptured. For subsequent 3D reconstruction, images from different physical sections need to be spatially aligned by optimization of some functional. We present an optimization algorithm, which in the examined samples prevents artifacts produced by other methods
Trvalý link: http://hdl.handle.net/11104/0203557