Počet záznamů: 1  

Preconcentration and Detection of Mercury with Bioluminescent Bioreporter E. coli ARL1.

  1. 1.
    0453525 - ÚCHP 2016 RIV DE eng J - Článek v odborném periodiku
    Solovyev, Andrey - Koštejn, Martin - Kuncová, Gabriela - Dostálek, P. - Rohovec, Jan - Navrátil, Tomáš
    Preconcentration and Detection of Mercury with Bioluminescent Bioreporter E. coli ARL1.
    Applied Microbiology and Biotechnology. Roč. 99, č. 20 (2015), s. 8793-8802. ISSN 0175-7598. E-ISSN 1432-0614
    Institucionální podpora: RVO:67985858 ; RVO:67985831
    Klíčová slova: mercury detection * bioreporters * biosorbents
    Kód oboru RIV: CC - Organická chemie
    Impakt faktor: 3.376, rok: 2015

    Cell wall envelopes treated with sodium hydroxide and spray-dried were used as mercury sorbents. The sorbent having sorption capacity 17.7 ± 0.1 μmol/g determined was employed for preconcentration of mercury containing 1–10 ng/L. After preconcentration, bioavailable mercury was detected in samples of soil, stream, and tap water via induction of bioluminescence of E. coli ARL1. Iron and manganese at concentrations of tenth microgram per liter interfered bioluminescence detection of mercury. In tap water was detected semiquantitatively 0.127 ± 0.1 nmol/L by the induction of bioluminescence of E. coli ARL1 in medium with tryptone after preconcentration using a method of standard addition.
    Trvalý link: http://hdl.handle.net/11104/0254317

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    0453525.pdf61.8 MBAutorský postprintpovolen
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.