Počet záznamů: 1  

A nonfitting method using a spatial sine window transform for inhomogeneous effective-diffusion measurements by FRAP

  1. 1.
    0366298 - BFÚ 2012 RIV US eng J - Článek v odborném periodiku
    Orlova, Darya Yu - Bártová, Eva - Maltsev, V.P. - Kozubek, Stanislav - Chernyshev, A.V.
    A nonfitting method using a spatial sine window transform for inhomogeneous effective-diffusion measurements by FRAP.
    Biophysical Journal. Roč. 100, č. 2 (2011), s. 507-516. ISSN 0006-3495. E-ISSN 1542-0086
    Grant CEP: GA MŠMT(CZ) LC06027; GA MŠMT(CZ) LC535; GA MŠMT(CZ) ME 919
    Výzkumný záměr: CEZ:AV0Z50040507; CEZ:AV0Z50040702
    Klíčová slova: FRAP * diffusion coefficient * HP1 protein
    Kód oboru RIV: BO - Biofyzika
    Impakt faktor: 3.653, rok: 2011

    Effective diffusion coefficient was studied by biophysical approaches. Protein transport was studied by conventional FRAP technique and images were acquired by laser scanning confocal microscope.
    Trvalý link: http://hdl.handle.net/11104/0201345

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.