Heat and mass transfer caused by a laminar channel flow equipped with a synthetic jet array

  1. 1.
    0366206 - ÚT 2012 RIV US eng J - Článek v odborném periodiku
    Trávníček, Zdeněk - Dančová, Petra - Kordík, Jozef - Vít, Tomáš - Pavelka, Miroslav
    Heat and mass transfer caused by a laminar channel flow equipped with a synthetic jet array.
    Journal of Thermal Science and Engineering Applications. Roč. 2, č. 4 (2011), 041006-041006. ISSN 1948-5085. E-ISSN 1948-5093
    Grant CEP: GA AV ČR(CZ) IAA200760801; GA ČR(CZ) GA101/09/1959
    Výzkumný záměr: CEZ:AV0Z20760514
    Klíčová slova: synthetic jet * flow control * naphthalene sublimation
    Kód oboru RIV: BK - Mechanika tekutin
    http://scitation.aip.org/getabs/servlet/GetabsServlet?prog=normal&id=JTSEBV000002000004041006000001&idtype=cvips&gifs=yes

    Low-Reynolds-number laminar channel flow with an active flow control by means of synthetic (zero-net-mass-flux) jets is investigated experimentally. The Reynolds number is in a range 200–500. Measurements have been performed in macroscale in air and water, by means of the hot-wire anemometry, naphthalene sublimation technique, and PIV. The results show an influence of synthetic jets. The stagnation Nusselt number is enhanced by 10–30 times in comparison with the non-actuated channel flow. The results indicate that the present arrangement can be a useful tool for heat transfer enhancement in various applications, e.g., cooling and mixing.