Počet záznamů: 1  

Interlock system for the COMPASS tokamak

  1. 1.
    0349232 - ÚFP 2011 RIV CH eng J - Článek v odborném periodiku
    Hron, Martin - Sova, J. - Šíba, J. - Kovář, J. - Adámek, Jiří - Pánek, Radomír - Havlíček, Josef - Písačka, Jan - Mlynář, Jan - Stöckel, Jan
    Interlock system for the COMPASS tokamak.
    Fusion Engineering and Design. Roč. 85, 3-4 (2010), s. 505-508. ISSN 0920-3796. E-ISSN 1873-7196.
    [IAEA Technical Meeting on Control, Data Acquisition and Remote Participation for Fusion Research/7th./. Aix – en – Provence, 15.06.2009-19.06.2009]
    Grant CEP: GA MŠMT 7G09042; GA ČR GD202/08/H057
    Výzkumný záměr: CEZ:AV0Z20430508
    Klíčová slova: Tokamak operation * Interlock * Personnel safety
    Kód oboru RIV: BL - Fyzika plazmatu a výboje v plynech
    Impakt faktor: 1.143, rok: 2010
    http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6V3C-5003BXW-1&_user=6542793&_coverDate=07%2F31%2F2010&_rdoc=1&_fmt=high&_orig=search&_origin=search&_sort=d&_docanchor=&view=c&_acct=C000070123&_version=1&_urlVersion=0&_userid=6542793&md5=ef5794d05cc6530a905d1de43aa0ac6a&searchtype=a

    The COMPASS tokamak has started its operation recently at the Institute of Plasma Physics ASCRin Prague, Czech Republic. An important issue of the operation is the interlock system, which secures the safety of the personnel. The personnel protection is based on a restricted access into the experimental hall during the tokamak operation. An experimental hall access system, based on Honeywell WIN-PAKTM2005, allows to set the status of the experimental area and to control the movement of the personnel. A hardware interlock, based on a PLC connected on PESNET bus, interprets the experimental hall status and controls the safety of the operation of key systems accordingly. The permit for operation is granted and the real status of the systems is reported by hard-wired potential-less contacts. Visualization PC creates an operator interface, on which is running a .NET application; this PC is connected with PLC via PESNET bus. Details of the set-up are described in this contribution.
    Trvalý link: http://hdl.handle.net/11104/0189528

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.