Počet záznamů: 1  

Characterization of HIFU transducers designed for sonochemistry application: Cavitation distribution and quantification

  1. 1.
    0336679 - ÚFCH JH 2011 RIV NL eng J - Článek v odborném periodiku
    Hallez, L. - Touyeraz, F. - Hihn, J. Y. - Klíma, Jiří - Guey, J.-L. - Spajer, M. - Bailly, Y.
    Characterization of HIFU transducers designed for sonochemistry application: Cavitation distribution and quantification.
    Ultrasonics. Roč. 50, č. 2 (2010), s. 310-317. ISSN 0041-624X. E-ISSN 1874-9968
    Výzkumný záměr: CEZ:AV0Z40400503
    Klíčová slova: HIFU * acoustic cavitation * MBSCL threshold * sonoreactors
    Kód oboru RIV: CG - Elektrochemie
    Impakt faktor: 1.599, rok: 2010

    Acoustic field distribution was determined in HIFU sonoreactors as well as localization of cavitation activity by crossing different techniques: modeling, hydrophone measurements, laser tomography and SCL measurements. Particular care was taken with quanti. cation of this last technique by pixels or photon counting. Cavitation bubbles generated by HIFU are mainly located on the outer layer of the propagation cone in the post-focal zone. Greatest acoustic activity is not located at the geometrical focal, but corresponds to a high concentration of bubbles zone. On the contrary, the main sonochemical activity shifts slightly toward the transducer, whereas quenching of inertial cavitation is observed directly at the focal. Finally, SCL thresholds have been determined.
    Trvalý link: http://hdl.handle.net/11104/0180864

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.