Počet záznamů: 1  

Calibration of the underground muon detector of the Pierre Auger Observatory

  1. 1.
    0548212 - FZÚ 2022 RIV GB eng J - Článek v odborném periodiku
    Aab, A. - Abreu, A. - Aglietta, M. - Bakalová, Alena - Blažek, Jiří - Boháčová, Martina - Chudoba, Jiří - Ebr, Jan - Hamal, Petr - Janeček, Petr - Juryšek, Jakub - Mandát, Dušan - Palatka, Miroslav - Pech, Miroslav - Prouza, Michael - Řídký, Jan - dos Santos, Eva M. Martins - Schovánek, Petr - Tobiška, Petr - Trávníček, Petr - Vícha, Jakub - Yushkov, Alexey … celkem 364 autorů
    Calibration of the underground muon detector of the Pierre Auger Observatory.
    Journal of Instrumentation. Roč. 16, č. 4 (2021), č. článku P04003. ISSN 1748-0221. E-ISSN 1748-0221
    Grant CEP: GA MŠMT LTT18004; GA MŠMT(CZ) EF18_046/0016010; GA MŠMT EF16_013/0001402; GA MŠMT LM2015038; GA MŠMT(CZ) LM2018102
    Grant ostatní: OP VVV - AUGERII.CZ(XE) CZ.02.1.01/0.0/0.0/18_046/0016010; OP VVV - AUGER-CZ(XE) CZ.02.1.01/0.0/0.0/16_013/0001402
    Institucionální podpora: RVO:68378271
    Klíčová slova: particle detectors * detector alignment and calibration methods (lasers, sources, particle-beams) * photon detectors for UV * visible and IR photons (solid state)
    Obor OECD: Particles and field physics
    Impakt faktor: 1.121, rok: 2021
    Způsob publikování: Open access

    To obtain direct measurements of the muon content of extensive air showers with energy above 10(16.5) eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10m(2)-modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m(2) close to the intersection of the shower axis with the ground to much less than one per m(2) when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them.

    Trvalý link: http://hdl.handle.net/11104/0324315

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    0548212.pdf02 MBCC LicenceVydavatelský postprintpovolen
     
Počet záznamů: 1  