Počet záznamů: 1  

Simultaneous voltammetric determination of free tryptophan, uric acid, xanthine and hypoxanthine in plasma and urine

  1. 1.
    0521718 - BFÚ 2021 RIV GB eng J - Článek v odborném periodiku
    Hasoň, Stanislav - Ostatná, Veronika - Fojta, Miroslav
    Simultaneous voltammetric determination of free tryptophan, uric acid, xanthine and hypoxanthine in plasma and urine.
    Electrochimica acta. Roč. 329, JAN 2020 (2020), č. článku 135132. ISSN 0013-4686. E-ISSN 1873-3859
    Grant CEP: GA ČR(CZ) GA18-18154S
    Institucionální podpora: RVO:68081707
    Klíčová slova: boron-doped diamond * pencil graphite * amino-acids * carbon electrodes * electrochemical oxidation
    Obor OECD: Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
    Impakt faktor: 6.901, rok: 2020
    Způsob publikování: Open access
    http://apps.webofknowledge.com/InboundService.do?customersID=Alerting&mode=FullRecord&IsProductCode=Yes&product=WOS&Init=Yes&Func=Frame&DestFail=http%3A%2F%2Fwww.webofknowledge.com&action=retrieve&SrcApp=Alerting&SrcAuth=Alerting&SID=F1U16JK9pRLeJ9ufBLv&UT=WOS%3A000498391900034

    We have designed an improved electrochemical analysis of clinical samples in bodily fluids. The method allows reliable identification of several coexisting substances (tryptophan, uric acid, xanthine and hypoxanthine) present on different physiological levels. We prepared in situ electrogenerated graphite oxides (GrO) directly on the surface of a graphite pencil electrode. GrO presence enhances electrooxidation signals of small aromatic molecules and can shift their oxidation potentials. The oxidation potentials of tryptophan and tyrosine in their free and protein-bound forms, and free xanthine are very close to each other on common carbon-based materials. We found that free tryptophan's oxidation signal is significantly more enhanced (about 11-times) than the free tyrosine signal (only negligibly in the given conditions). Distinguishing xanthine's oxidation signal from that of the free tryptophan is allowed by their approximately 60 mV separation, sufficient for parallel determination by signal deconvolution. Additionally, we show that proteins containing tyrosine and/or tryptophan behave as electro-inactive and do not interfere with free amino acid determination on the GrO-modified graphite electrodes, while they strongly influence all species' detection on other carbon-based materials. Determining all individual compounds was possible at corresponding physiological values after sole dilution of human plasma (urine) and direct measurement with no pre-separation steps. (C) 2019 Elsevier Ltd. All rights reserved.
    Trvalý link: http://hdl.handle.net/11104/0306308

     
     