Počet záznamů: 1  

Evaluation of silica from different vendors as the solid support of anion-exchange chiral stationary phases by means of preferential sorption and liquid chromatography.

  1. 1.
    0511718 - ÚCHP 2020 RIV DE eng J - Článek v odborném periodiku
    Kohout, P. - Hovorka, Š. - Herciková, J. - Wilk, M. - Sysel, P. - Izák, Pavel - Bartůněk, V. - von Baeckmann, C. - Pícha, Jan - Frühauf, P.
    Evaluation of silica from different vendors as the solid support of anion-exchange chiral stationary phases by means of preferential sorption and liquid chromatography.
    Journal of Separation Science. Roč. 42, č. 24 (2019), s. 3653-3661. ISSN 1615-9306. E-ISSN 1615-9314
    Grant CEP: GA ČR(CZ) GA17-00089S
    Institucionální podpora: RVO:67985858 ; RVO:61388963
    Klíčová slova: chiral anion exchanger * preferential sorption * liquid chromatography
    Obor OECD: Chemical process engineering; Analytical chemistry (UOCHB-X)
    Impakt faktor: 2.878, rok: 2019
    Způsob publikování: Omezený přístup

    Chromatographic performance of a chiral stationary phase is significantly influenced by the employed solid support. Properties of the most commonly used support, silica particles, such as size and size distribution, and pore size are of utmost importance for both superficially porous particles and fully porous particles. In this work, we have focused on evaluation of fully porous particles from three different vendors as solid supports for a brush-type chiral stationary phase based on 9-O-tert-butylcarbamoyl quinidine. We have prepared corresponding stationary phases under identical experimental conditions and determined the parameters of the modified silica by physisorption measurements and scanning electron microscopy. Enantiorecognition properties of the chiral stationary phases have been studied using preferential sorption experiments. The same material was slurry-packed into chromatographic columns and the chromatographic properties have been evaluated in liquid chromatography. We show that preferential sorption can provide valuable information about the influence of the pore size and total pore volume on the interaction of analytes of different size with the chirally-modified silica surface. The data can be used to understand differences observed in chromatographic evaluation of the chiral stationary phases. The combination of preferential sorption and liquid chromatography separation can provide detailed information on new chiral stationary phases.
    Trvalý link: http://hdl.handle.net/11104/0303439

     
    Název souboruStaženoVelikostKomentářVerzePřístup
    0511718.pdf01.9 MBVydavatelský postprintvyžádat
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.