Počet záznamů: 1  

Calibration-free quantitative elemental analysis of meteor plasma using reference laser-induced breakdown spectroscopy of meteorite samples

  1. 1.
    0484218 - ÚFCH JH 2018 RIV FR eng J - Článek v odborném periodiku
    Ferus, Martin - Koukal, J. - Lenža, Libor - Srba, J. - Kubelík, Petr - Laitl, V. - Zanozina, Ekaterina M. - Váňa, Pavel - Kaiserová, Tereza - Knížek, Antonín - Rimmer, P. - Chatzitheodoridis, E. - Civiš, Svatopluk
    Calibration-free quantitative elemental analysis of meteor plasma using reference laser-induced breakdown spectroscopy of meteorite samples.
    Astronomy & Astrophysics. Roč. 610, FEB 2018 (2018), č. článku A73. ISSN 0004-6361. E-ISSN 1432-0746
    Grant CEP: GA ČR(CZ) GA14-12010S; GA ČR(CZ) GA18-27653S
    Grant ostatní: Akademie věd - GA AV ČR(CZ) R200401521; Akademie věd - GA AV ČR(CZ) R200401721; COST(XE) CM1104; COST(XE) TD1308; RFBR(RU) 16-32-00034
    Institucionální podpora: RVO:61388955
    Klíčová slova: astrochemistry * spectroscopic techniques * calibration-free LIBS * plasma simulation
    Obor OECD: Physical chemistry
    Impakt faktor: 6.209, rok: 2018
    Způsob publikování: Open access

    Aims. We aim to analyse real-time Perseid and Leonid meteor spectra using a novel calibration-free (CF) method, which is usually
    applied in the laboratory for laser-induced breakdown spectroscopic (LIBS) chemical analysis.
    Methods. Reference laser ablation spectra of specimens of chondritic meteorites were measured in situ simultaneously with a highresolution
    laboratory Echelle spectrograph and a spectral camera for meteor observation. Laboratory data were subsequently evaluated
    via the CF method and compared with real meteor emission spectra. Additionally, spectral features related to airglow plasma were
    compared with the spectra of laser-induced breakdown and electric discharge in the air.
    Results. We show that this method can be applied in the evaluation of meteor spectral data observed in real time. Specifically, CF
    analysis can be used to determine the chemical composition of meteor plasma, which, in the case of the Perseid and Leonid meteors
    analysed in this study, corresponds to that of the C-group of chondrites.
    Trvalý link: http://hdl.handle.net/11104/0279355

     