Počet záznamů: 1  

Note: Electronic circuit for two-way time transfer via a single coaxial cable with picosecond accuracy and precision

  1. 1.
    0387766 - ÚFE 2013 RIV US eng J - Článek v odborném periodiku
    Pánek, Petr - Procházka, I. - Kodet, J.
    Note: Electronic circuit for two-way time transfer via a single coaxial cable with picosecond accuracy and precision.
    Review of Scientific Instruments. Roč. 83, č. 11 (2012), s. 1161041-1161043. ISSN 0034-6748. E-ISSN 1089-7623
    Grant CEP: GA MPO(CZ) FR-TI3/453
    Institucionální podpora: RVO:67985882
    Klíčová slova: time measurement
    Kód oboru RIV: JA - Elektronika a optoelektronika, elektrotechnika
    Impakt faktor: 1.602, rok: 2012

    An electronic circuit for two-way time transfer with sub-picosecond precision and systematic error of a few pisoseconds was designed, constructed, and tested.The concept of the circuit and key timing parameters are presented.
    Trvalý link: http://hdl.handle.net/11104/0220334

     
     