Počet záznamů: 1  

Significance of independent radon entry rate and air exchange rate assessment for the purpose of radon mitigation effectiveness proper evaluation: case studies

  1. 1.
    0360283 - ÚI 2012 RIV GB eng J - Článek v odborném periodiku
    Froňka, A. - Jílek, K. - Moučka, L. - Brabec, Marek
    Significance of independent radon entry rate and air exchange rate assessment for the purpose of radon mitigation effectiveness proper evaluation: case studies.
    Radiation Protection Dosimetry. Roč. 145, 2-3 (2011), s. 133-137. ISSN 0144-8420. E-ISSN 1742-3406
    Výzkumný záměr: CEZ:AV0Z10300504
    Klíčová slova: indoor radon * kalman filter * state-space modeling
    Kód oboru RIV: BB - Aplikovaná statistika, operační výzkum
    Impakt faktor: 0.822, rok: 2011

    Two new single-family houses identified as insufficient with regard to existing radon barrier efficiency, have been selected for further examination. A complex set of radon diagnosis procedures has been applied in order to localise and quantify radon entry pathways into the indoor environment. Independent assessment of radon entry rate and air exchange rate has been carried out using the continuous indoor radon measurement and a specific tracer gas application. Simultaneous assessment of these key determining factors has turned out to be absolutely crucial in the context of major cause identification of elevated indoor radon concentration.
    Trvalý link: http://hdl.handle.net/11104/0197871

     
     