Počet záznamů: 1  

PENT test versus time to rupture curve for HDPE

  1. 1.
    0354122 - ÚFM 2012 RIV CA eng O - Ostatní výsledky
    Nezbedová, E. - Hutař, Pavel - Knésl, Zdeněk
    PENT test versus time to rupture curve for HDPE.
    2010
    Grant CEP: GA ČR GA106/09/0279; GA ČR GC101/09/J027
    Výzkumný záměr: CEZ:AV0Z20410507
    Klíčová slova: HDPE * crack propagation * PENT test
    Kód oboru RIV: JL - Únava materiálu a lomová mechanika

    The service life for HDPE (PE 80, PE 100) materials used in plastic pipes application covers a time span of up 50 years. The new type of PE 100 (PE 100 RC) should achieve the life time over 100 years. Conventional hydrostatic pressure test to qualify a new resin must last 104 hours (ISO 1167). In the last twenty years two accelerated tests that produce the same type of brittle fracture that occurs in pipes after long time in service were developed and standardized (PENT and FNCT tests). In contrast to FNCT, PENT enables to follow the kinetics of slow crack growth (SCG) and estimates some relevant parameters (time for SCG initiation, rate of SCG and time to failure). These experimentally data, which can be described by exponential relationship in combination with numerical simulation of slow crack growth enable to described the part of time to rupture curve that is responsible for service lifetime. This procedure can substitute time consuming and expensive testing.
    Trvalý link: http://hdl.handle.net/11104/0193194

     
     