Počet záznamů: 1  

Measurement Accuracy of a Mono-fiber Optical Probe in a Bubbly Flow

  1. 1.
    0343074 - ÚCHP 2011 RIV GB eng J - Článek v odborném periodiku
    Vejražka, Jiří - Večeř, M. - Orvalho, Sandra - Sechet, Ph. - Růžička, Marek - Cartellier, A.
    Measurement Accuracy of a Mono-fiber Optical Probe in a Bubbly Flow.
    International Journal of Multiphase Flow. Roč. 36, č. 7 (2010), s. 533-548. ISSN 0301-9322. E-ISSN 1879-3533
    Grant CEP: GA ČR GA104/07/1110; GA ČR GP104/06/P287; GA AV ČR(CZ) IAA200720801
    Výzkumný záměr: CEZ:AV0Z40720504
    Klíčová slova: optical probe * bubble-fiber interaction * void fraction
    Kód oboru RIV: CI - Průmyslová chemie a chemické inženýrství
    Impakt faktor: 1.772, rok: 2010

    The measurement accuracy of a mono-fiber optical probe is studied experimentally using isolated bubbles rising freely in a still liquid. The dwell time of the probe tip within the gas phase, which is obtained from both the optical probe signal and high-speed visualization, is compared with the dwell time expected for a non-perturbed bubble. The measurement error results mainly from the intrusive nature of the optical probe, which modifies the behavior of the bubble when it comes into contact with the probe tip. The measured dwell time therefore differs from its ideal value that would be found with an unperturbed bubble. For a wetting liquid, the interaction increases the dwell time if the bubble is pierced near its pole, and shortens it for piercing near the equator. It is shown that the error can be correlated with a modified Weber number, and this correlation is helpful for sensor selection and for uncertainty estimate.
    Trvalý link: http://hdl.handle.net/11104/0185636

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.