Počet záznamů: 1
Characterization of HIFU transducers designed for sonochemistry application: Cavitation distribution and quantification
- 1.0336679 - ÚFCH JH 2011 RIV NL eng J - Článek v odborném periodiku
Hallez, L. - Touyeraz, F. - Hihn, J. Y. - Klíma, Jiří - Guey, J.-L. - Spajer, M. - Bailly, Y.
Characterization of HIFU transducers designed for sonochemistry application: Cavitation distribution and quantification.
Ultrasonics. Roč. 50, č. 2 (2010), s. 310-317. ISSN 0041-624X. E-ISSN 1874-9968
Výzkumný záměr: CEZ:AV0Z40400503
Klíčová slova: HIFU * acoustic cavitation * MBSCL threshold * sonoreactors
Kód oboru RIV: CG - Elektrochemie
Impakt faktor: 1.599, rok: 2010
Acoustic field distribution was determined in HIFU sonoreactors as well as localization of cavitation activity by crossing different techniques: modeling, hydrophone measurements, laser tomography and SCL measurements. Particular care was taken with quanti. cation of this last technique by pixels or photon counting. Cavitation bubbles generated by HIFU are mainly located on the outer layer of the propagation cone in the post-focal zone. Greatest acoustic activity is not located at the geometrical focal, but corresponds to a high concentration of bubbles zone. On the contrary, the main sonochemical activity shifts slightly toward the transducer, whereas quenching of inertial cavitation is observed directly at the focal. Finally, SCL thresholds have been determined.
Trvalý link: http://hdl.handle.net/11104/0180864
Počet záznamů: 1