Počet záznamů: 1  

Random errors in time interval measurement based on SAW filter excitation

  1. 1.
    0309199 - ÚFE 2008 RIV US eng J - Článek v odborném periodiku
    Pánek, Petr
    Random errors in time interval measurement based on SAW filter excitation.
    [Náhodné chyby při měření časového intervalu založeném na excitaci filtru s povrchovou akustickou vlnou.]
    IEEE Transactions on Instrumentation and Measurement. Roč. 57, č. 6 (2008), s. 1244-1250. ISSN 0018-9456. E-ISSN 1557-9662
    Výzkumný záměr: CEZ:AV0Z20670512
    Klíčová slova: time measurement
    Kód oboru RIV: JA - Elektronika a optoelektronika, elektrotechnika
    Impakt faktor: 0.978, rok: 2008

    The paper deals with the time interval measurement method that makes use of a surface acoustic wave filter as a time interpolator. The noise contribution to the overall time interval measurement error has been analyzed. Four noise sources have been considered: noise of excitation, noise of amplifier, quantization noise of the analog-to-digital converter, and sampling jitter. The theoretical results have been compared to simulations.

    Článek se věnuje metodě měření časového intervalu, která využívá jako časový interpolátor filtr s povrchovou akustickou vlnou. Je zde provedena analýza příspěvku šumu k celkové chybě měření časového intervalu. Uvažovali jsme přitom čtyři zdroje šumu: šum excitace, šum zesilovače, kvantizační šum analogově-číslicového převodníku a jitter vzorkování. Teoretické výsledky byly porovnány s výsledky simulace.
    Trvalý link: http://hdl.handle.net/11104/0161411

     
     