Počet záznamů: 1  

An integrated optic hydrogen sensor based on SPR on palladium

  1. 1.
    0303792 - URE-Y 20010014 RIV CH eng J - Článek v odborném periodiku
    Tobiška, Petr - Hugon, O. - Trouillet, A. - Gagnaire, H.
    An integrated optic hydrogen sensor based on SPR on palladium.
    Sensors and Actuators B - Chemical. B74, 1/3 (2001), s. 168-172. ISSN 0925-4005. E-ISSN 0925-4005.
    [European Conference on Optical Chemical Sensors and Biosensors EUROPT(R)ODE /5./. Lyon-Villeurbanne, 16.04.2000-19.04.2000]
    Grant CEP: GA ČR GA102/99/0549
    Výzkumný záměr: CEZ:AV0Z2067918
    Klíčová slova: hydrogen * integrated optics * surface plasmon resonance
    Kód oboru RIV: JB - Senzory, čidla, měření a regulace
    Impakt faktor: 1.440, rok: 2001

    A small and efficient hydrogen sensor was realized using surface plasmon resonance in integrated optical waveguide. The attenuation coefficient of the device is modified by the presence of thin palladium layer whose optical constants are influenced by hydrogen concentration of the surrounding medium. A modal analysis of the sensor structure is performed and a simple model is proposed to assist in the structure design and optimisation. Finally, experimental results for hydrogen detection are presented.
    Trvalý link: http://hdl.handle.net/11104/0113976
     

Počet záznamů: 1  