Počet záznamů: 1  

Erosion of the Post-Buckled Reserve of Strength ofThin-Walld Structures Due to Cumulative Damage

  1. 1.
    0210269 - UTAM-F 20013024 RIV SIGLE GB eng C - Konferenční příspěvek (zahraniční konf.)
    Škaloud, Miroslav - Zörnerová, Marie
    Erosion of the Post-Buckled Reserve of Strength ofThin-Walld Structures Due to Cumulative Damage.
    Proceedings of the Third International Conference onThin-Walled Structures. Oxford: Elsevier, 2001, s. 137-144.
    [Thin-Walled Structures. Krakov (PL), 05.06.2001-07.06.2001]
    Výzkumný záměr: CEZ:AV0Z2071913
    Klíčová slova: Breathing,cumulative damage,fatigue crack.
    Kód oboru RIV: JM - Inženýrské stavitelství

    The plate elements of steel bridges "breathe" under themany times repeated loading. This phenomenon generatescumulative damage in webs and the initiation of fatiguecracks.Based on experiments two approaches to the definitionof limit state are discussed.
    Trvalý link: http://hdl.handle.net/11104/0105823


     
     