Počet záznamů: 1  

Influence of Higher Spatial Harmonics on Operation of Rotating Machines with Magnetic Rotor Saliency

  1. 1.
    0195445 - UE-C 20004018 RIV FI eng C - Konferenční příspěvek (zahraniční konf.)
    Schreier, Luděk - Doležel, Ivo - Chomát, Miroslav
    Influence of Higher Spatial Harmonics on Operation of Rotating Machines with Magnetic Rotor Saliency.
    International Conference on Electrical Machines ICEM 2000. Helsinki: Helsinki University of Technology, 2000, s. 1656-1660. ISBN 951-22-5097-7.
    [International Conference on Electrical Machines ICEM 2000. Espoo (FI), 28.08.2000-30.08.2000]
    Grant CEP: GA ČR GA102/97/0464; GA ČR GA102/00/0360
    Kód oboru RIV: JA - Elektronika a optoelektronika, elektrotechnika

    The paper deals with the rise of higher space harmonics of the magnetic flux density in the air gap of modern unconventional machines characterised by a relatively complicated shape of the air gap resulting in non-uniform distribution of the magnetic..