Application of high-resolution capillary array electrophoresis with automated fraction collection for GeneCalling analysis of the yeast genomic DNA
- 1.0162489 - UIACH-O 20033049 RIV DE eng J - Článek v odborném periodiku
Berka, J. - Ruiz-Martinez, M. C. - Hammond, R. - Minarik, M. - Foret, František - Sosic, Z. - Klepárník, Karel - Karger, B. L.
Application of high-resolution capillary array electrophoresis with automated fraction collection for GeneCalling analysis of the yeast genomic DNA.
Electrophoresis. Roč. 24, č. 4 (2003), s. 639-647. ISSN 0173-0835. E-ISSN 1522-2683
Grant CEP: GA ČR GA203/00/0772; GA ČR GA303/00/0928
Výzkumný záměr: CEZ:AV0Z4031919
Klíčová slova: capillary array * fraction collection * gene expression profiling
Kód oboru RIV: CB - Analytická chemie, separace
Impakt faktor: 4.040, rok: 2003
Capillary array instrument was applied to transcript profiling of the yeast genomic DNA using GeneCaliing'" chemistry. The instrument integrated a 12-capillary array for DNA separation with a replaceable sieving matrix, laser-induced fluorescence detection and an automated microfraction collector. The DNA fractions, exiting the separation capillaries, were continuously deposited in a 1536-well collection plate made of agarose gel. DNA fragments recovered from selected fractions were cloned and then sequenced. Over 80% of theoretically predicted fragments could be recovered in the collected fractions, cloned and sequenced with an average redundancy of threefold. Excellent correlation of the experimentally obtained sequences with the theoretically predicted gene fragments demonstrated the suitability of capillary array electrophoresisfor micropreparative recovery of DNA fragments. This approach, useful especially for rapid DNA expression profiling of unknown genes for nonsequenced organisms, demonstrates the practical capability of the prototype multicapillary fraction collector.
Trvalý link: http://hdl.handle.net/11104/0059802