Počet záznamů: 1  

Bio-compatibility of the surface layer of pyrolytic graphite

  1. 1.
    0142539 - FGU-C 20030096 RIV CH eng J - Článek v odborném periodiku
    Starý, V. - Bačáková, Lucie - Horník, J. - Chmelík, V.
    Bio-compatibility of the surface layer of pyrolytic graphite.
    Thin Solid Films. Roč. 433, 1-2 (2003), s. 191-198. ISSN 0040-6090. E-ISSN 1879-2731
    Grant CEP: GA ČR GA106/99/0626; GA MŠMT OC 527.130
    Výzkumný záměr: CEZ:AV0Z5011922; CEZ:MSM 210000012
    Klíčová slova: carbon-carbon composite * pyrolytic graphite * cell adhesion
    Kód oboru RIV: JI - Kompozitní materiály
    Impakt faktor: 1.598, rok: 2003

    Carbon-fibre reinforced carbon composites, i.e. materials developed for potential use in orthopaedic and dental surgery, were coated with pyrolytic graphite. The surface roughness was adjusted by grinding and polishing with metallographic paper and/or diamond paste. There is a statistically significant correlation of surface roughness parameters with adhesion and proliferation of osteogenic MG-63 cells.
    Trvalý link: http://hdl.handle.net/11104/0040240
     

Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.