Počet záznamů: 1  

Method of processing ion energy distributions using a Thomson parabola ion spectrograph with a microchannelplate image converter camera

  1. 1.
    0133106 - FZU-D 20000469 RIV US eng J - Článek v odborném periodiku
    Mróz, W. - Norek, P. - Prokopiuk, A. - Parys, P. - Pfeifer, Miroslav - Láska, Leoš - Stöckli, M. - Fry, D. - Kasuya, K.
    Method of processing ion energy distributions using a Thomson parabola ion spectrograph with a microchannelplate image converter camera.
    Review of Scientific Instruments. Roč. 71, č. 3 (2000), s. 1417-1420. ISSN 0034-6748. E-ISSN 1089-7623
    Výzkumný záměr: CEZ:AV0Z1010921
    Kód oboru RIV: BL - Fyzika plazmatu a výboje v plynech
    Impakt faktor: 1.239, rok: 2000

    This paper describes a method of processing experimental results, obtained from a Thomson parabola ion spectrograph,using a microchannelplate image convertor. Ion energy distribution for C1+ -- C6+ and Ta1+ -- Ta12+ are shown, and the effects of correcting the obtained ion energy distributions for the detection efficiency of the microchannelplate are illustrated.
    Trvalý link: http://hdl.handle.net/11104/0031094


     
     

Počet záznamů: 1  