Počet záznamů: 1  

Comparison of different LIDT testing protocols for PW and multi-PW class high reflectivity coatings

  1. 1.
    SYSNO ASEP0521895
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevComparison of different LIDT testing protocols for PW and multi-PW class high reflectivity coatings
    Tvůrce(i) Ďurák, Michal (FZU-D) RID
    Kramer, Daniel (FZU-D) RID
    Velpula, Praveen K. (FZU-D)
    Meadows, A.R. (US)
    Cupal, Josef (FZU-D) ORCID
    Rus, Bedřich (FZU-D) ORCID
    Celkový počet autorů6
    Číslo článku100140O
    Zdroj.dok.Laser-Induced Damage in Optical Materials 2016. - Bellingham : SPIE, 2016 / Exarhos G.J. ; Gruzdev V.E. ; Menapace J.A. ; Ristau D. ; Soileau M.J. - ISSN 0277-786X - ISBN 978-1-5106-0437-7
    Rozsah stranroč. 10014 (2016), s. 1-3
    Poč.str.13 s.
    Forma vydáníTištěná - P
    AkceAnnual Laser Damage Symposium on Optical Materials for High-Power Lasers /48./
    Datum konání25.09.2015 - 28.09.2015
    Místo konáníBoulder, CO
    ZeměUS - Spojené státy americké
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovalaser damage ; threshold ; raster scan ; femtosecond ; petawatt ; vacuum
    Vědní obor RIVBH - Optika, masery a lasery
    Obor OECDOptics (including laser optics and quantum optics)
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000394528400015
    EID SCOPUS85015672339
    DOI10.1117/12.2245182
    AnotaceDevelopment of state-of-the-art high-power laser systems requires accurate information about the damage resistance of critical optical components. Since damage threshold fluence decreases significantly with decreasing pulse length, highpower systems based on chirped-pulse amplification are usually limited by the damage threshold of the components utilized for the final pulse compression and transport of the compressed beams. Sub-picosecond laser damage is a complex process involving various nonlinear photoionization and relaxation mechanisms, and no current theory can reliably predict damage threshold values for arbitrary combinations of laser parameters, optical coating properties, and ambient conditions. To evaluate the damage resistance of candidate high-reflectivity coatings for the distribution of compressed PW and multi-PW pulses within experimental areas of the ELI beamlines facility, a series of laser damage tests in high vacuum were conducted. In this work, we present threshold values for high-reflectance (HR) dielectric coatings tested according to different protocols in conditions specific to their operation. We compare results acquired using S-on-1, R-on-1, and Raster Scan routines for several samples and discuss their accuracy.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2020
Počet záznamů: 1  