Removal of HCI and SO2 from Flue Gas on a Small Scale.

  1. 1.
    SYSNO ASEP0509598
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVO - Ostatní
    NázevRemoval of HCI and SO2 from Flue Gas on a Small Scale.
    Tvůrce(i) Zach, Boleslav (UCHP-M) ORCID, RID, SAI
    Šyc, Michal (UCHP-M) RID, SAI, ORCID
    Pohořelý, Michael (UCHP-M) RID, ORCID, SAI
    Moško, Jaroslav (UCHP-M) RID, ORCID, SAI
    Brynda, Jiří (UCHP-M) RID, ORCID, SAI
    Václavková, Šárka (UCHP-M) RID, ORCID, SAI
    Svoboda, Karel (UCHP-M) RID, ORCID, SAI
    Punčochář, Miroslav (UCHP-M) RID, ORCID, SAI
    Číslo článku021
    Zdroj.dok.Proceedings Sardinia 2019. - Padova : CISA Publisher, 2019
    Poč.str.6 s.
    Forma vydáníNosič - C
    AkceInternational Waste Management and Landfill Symposium /17./
    Datum konání30.09.2019 - 04.10.2019
    Místo konáníCagliari
    ZeměIT - Itálie
    Typ akceEUR
    Jazyk dok.eng - angličtina
    Země vyd.IT - Itálie
    Klíč. slovaflue gas treatment ; dry sorption ; acid gases
    Vědní obor RIVJP - Průmyslové procesy a zpracování
    Obor OECDRemote sensing
    CEPLTC17051 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    TE02000236 GA TA ČR - Technologická agentura ČR
    Institucionální podporaUCHP-M - RVO:67985858
    AnotaceWith landfill bans emerging across Europe, it is necessary to choose proper alternatives to landfilling. One of the alternatives can be waste-to-energy, specifically in the form of waste incineration. In some cases, such as areas with low population density, small units can be the only way to avoid large collection areas. However, in the case of incineration, it is also necessary to have a small-scale flue gas treatment. The use of flue gas treatment in a very small-scale requires its simplification. Therefore, the removal of HCl and SO2 by sodium bicarbonate at conditions allowing simultaneous removal or other pollutants was investigated. The results show that, in the case sodium bicarbonate, the reaction rate of HCl was higher than the reaction rate of SO2. The achieved sorbent conversion depended significantly on the concentration of HCl. High concentrations of HCl diminished the ability of the sorbent to remove SO2 and caused, thereby, lower conversion of the sorbent because it had to be present in higher excess to achieve the desired concentration of SO2 in the clean flue gas.