Počet záznamů: 1  

Surface chemical stability of differently terminated nanocrystalline diamond films

  1. 1.
    SYSNO ASEP0502338
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevSurface chemical stability of differently terminated nanocrystalline diamond films
    Tvůrce(i) Artemenko, Anna (FZU-D) RID, ORCID
    Varga, Marián (FZU-D) RID, ORCID
    Dragounová, Kateřina (FZU-D) ORCID
    Kromka, Alexander (FZU-D) RID, ORCID, SAI
    Celkový počet autorů4
    Zdroj.dok.Conference proceedings of the 20th School of Vacuum Technology - Nanoelectronics and Vacuum. - Bratislava : Slovenská vákuová spoločnosť, 2018 / Michalka M. ; Vincze A. - ISBN 978-80-99905-00-0
    Rozsah strans. 53-55
    Poč.str.3 s.
    Forma vydáníOnline - E
    AkceSchool of Vacuum Technology - Nanoelectronics and Vacuum /20./
    Datum konání23.10.2018 - 26.10.2018
    Místo konáníŠtrbské Pleso
    ZeměSK - Slovensko
    Typ akceEUR
    Jazyk dok.eng - angličtina
    Země vyd.SK - Slovensko
    Klíč. slovadiamond ; termination ; stability ; sterilization
    Vědní obor RIVBM - Fyzika pevných látek a magnetismus
    Obor OECDCondensed matter physics (including formerly solid state physics, supercond.)
    CEPNV15-33018A GA MZd - Ministerstvo zdravotnictví
    Institucionální podporaFZU-D - RVO:68378271
    AnotaceCarbon-based material such as nanocrystalline diamond (NCD) exhibits extraordinary properties suitable for biomedical applications. Here, proper diamond surface functionalization as well as its stability against sterilization methods (e.g. ultra-sonication, dry heat, autoclave, etc.) play a crucial role for such applications. This study focuses on the evaluation of surface chemical stability of H/O/F-terminated NCD films against autoclave, ultra-sonication and ethanol treatment. The NCD films were grown on silicon substrates by a microwave plasma enhanced chemical vapor deposition method. The as grown NCD films were chemically terminated with hydrogen, oxygen and fluor containing functional groups using appropriate plasma process. The H/O/F-terminated NCD films after autoclave, ultra-sonication and ethanol treatment were investigated by scanning electron microscope (SEM), X-ray photoelectron spectroscopy (XPS), Raman spectroscopy and water contact angle (WCA) measurements.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2019
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.