Počet záznamů: 1  

Novel Approach In Binary Nucleation Experiments Performed Under Laboratory Conditions.

  1. 1.
    SYSNO ASEP0496656
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevNovel Approach In Binary Nucleation Experiments Performed Under Laboratory Conditions.
    Tvůrce(i) Škrabalová, Lenka (UCHP-M) RID
    Trávníčková, Tereza (UCHP-M) RID, ORCID, SAI
    Havlica, Jaromír (UCHP-M) RID, ORCID, SAI
    Krejčí, Petr (UCHP-M)
    Hrubý, Jan (UT-L) RID, ORCID
    Ždímal, Vladimír (UCHP-M) RID, ORCID, SAI
    Zdroj.dok.Proceedings of the 20th International Conference on Nucleation and Atmospheric Aerosols. - Helsinki : Kirjapaino Hermes Oy, 2017 / Halonen R. ; Nikandrova A. ; Kontkanen J. - ISSN 0784-3496 - ISBN 978-952-7091-85-2
    Rozsah strans. 187-188
    Poč.str.2 s.
    Forma vydáníOnline - E
    AkceInternational Conference on Nucleation and Atmospheric Aerosols /20./
    Datum konání25.06.2017 - 30.06.2017
    Místo konáníHelsinki
    ZeměFI - Finsko
    Typ akceEUR
    Jazyk dok.eng - angličtina
    Země vyd.FI - Finsko
    Klíč. slovabinary nucleation ; sulfuric acid – water ; laminar Co-flow tube
    Vědní obor RIVCF - Fyzikální chemie a teoretická chemie
    Obor OECDPhysical chemistry
    Vědní obor RIV – spolupráceÚstav termomechaniky - Termodynamika
    CEPGAP105/12/0664 GA ČR - Grantová agentura ČR
    Institucionální podporaUCHP-M - RVO:67985858 ; UT-L - RVO:61388998
    AnotaceIn this work we introduce a novel device especially designed for binary or ternary nucleation experiments – a laminar co-flow tube (LCFT). The first experiments performed on this type of device were focused on binary nucleation of sulfuric acid-water. Main advantage of the co-flow design of LCFT is, that the turbulent mixing zone is not present. Simple modeling of laminar flow then leads to more accurate determination of location and composition of nucleation zone. The sheath flow of water vapor surrounding the axial sulfuric acid stream prevents the losses of H2SO4 on the chamber wall. A detailed description of the whole experimental device and validation of operational set-up parameters can be found here (Krejčí 2010). At this device, concentrations of newly formed nuclei versus time are measured as an input parameter for mathematical model.
    PracovištěÚstav chemických procesů
    KontaktEva Jirsová, jirsova@icpf.cas.cz, Tel.: 220 390 227
    Rok sběru2019
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.