Deformation analysis of the spongious sample in simulated physiological conditions based on in-situ compression, 4D computed tomography and fast readout detector

  1. 1.
    SYSNO ASEP0497305
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevDeformation analysis of the spongious sample in simulated physiological conditions based on in-situ compression, 4D computed tomography and fast readout detector
    Tvůrce(i) Fíla, Tomáš (UTAM-F) RID, SAI, ORCID
    Šleichrt, Jan (UTAM-F) RID, ORCID, SAI
    Kytýř, Daniel (UTAM-F) SAI, RID, ORCID
    Kumpová, Ivana (UTAM-F) RID, SAI, ORCID
    Vopálenský, Michal (UTAM-F) RID, ORCID, SAI
    Zlámal, Petr (UTAM-F) RID, SAI, ORCID
    Rada, Václav (UTAM-F) ORCID, SAI
    Vavřík, Daniel (UTAM-F) RID, SAI, ORCID
    Koudelka_ml., Petr (UTAM-F) RID, SAI, ORCID
    Senck, S. (AT)
    Celkový počet autorů10
    Číslo článkuC11021
    Zdroj.dok.Journal of Instrumentation. - : Institute of Physics Publishing - ISSN 1748-0221
    Roč. 13, November (2018)
    Poč.str.9 s.
    Forma vydáníTištěná - P
    AkceInternational Workshop on Radiation Imaging Detectors /20./
    Datum konání24.06.2018 - 28.06.2018
    Místo konáníSundsvall
    ZeměSE - Švédsko
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovacomputerized tomography (CT) ; computed radiography (CR) ; detection of defects ; inspection with x-rays
    Vědní obor RIVJJ - Ostatní materiály
    Obor OECDApplied mechanics
    CEPEF16_019/0000766 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    UT WOS000451408400003
    EID SCOPUS85057604044
    DOI10.1088/1748-0221/13/11/C11021
    AnotaceIn this work, an in-house designed table top loading device equipped with a bioreactor is used for the in-situ compression of a spongious sample in simulated physiological conditions. On-the-fly 4D computed tomography is used as a tool for the advanced volumetric analysis of the deforming microstructure of the specimen. The loading device with the bioreactor was placed directly onto the rotational stage of a modular X-ray scanner. As the loading device is equipped with a slip-ring cable system, it can perform an unlimited number of revolutions during the on-the-fly scanning procedure. A complementary metal-oxide-semiconductor flat panel detector with a fast readout was used for the acquisition of the X-ray images. The specimen was compressed with a low loading velocity. A set of the volumetric data capturing the deformation of the specimen during the experiment was prepared from the images acquired by the detector. A digital volume correlation algorithm was used for the evaluation of the volumetric strain fields in the specimen.