Počet záznamů: 1  

On-the-fly fast X-ray tomography using a CdTe pixelated detector – application in mechanical testing

  1. 1.
    0494940 - ÚTAM 2019 RIV US eng J - Článek v odborném periodiku
    Kumpová, Ivana - Vopálenský, Michal - Fíla, Tomáš - Kytýř, Daniel - Vavřík, Daniel - Pichotka, Martin - Jakůbek, Jan - Keršner, Z. - Klon, J. - Seitl, S. - Sobek, J.
    On-the-fly fast X-ray tomography using a CdTe pixelated detector – application in mechanical testing.
    IEEE Transactions on Nuclear Science. Roč. 65, č. 12 (2018), s. 2870-2876. ISSN 0018-9499. E-ISSN 1558-1578
    Grant CEP: GA MŠMT(CZ) EF16_019/0000766
    Institucionální podpora: RVO:68378297
    Klíčová slova: cadmium telluride (CdTe) detectors * fracture mechanics * material characterization * mechanical testing
    Obor OECD: Electrical and electronic engineering
    Impakt faktor: 1.428, rok: 2018
    https://ieeexplore.ieee.org/document/8482343

    Trvalý link: http://hdl.handle.net/11104/0288021
     